Chauvin Arnoux Ca 8336 User Manual카테고리 없음 2021. 1. 25. 23:35
July 21, 2014 | English | Español
Model 8336 - Cat. #2136.30
No SensorsModel 8336 - Cat. #2136.31
w/4 AmpFlex 193-24-BK SensorsModel 8336 - Cat. #2136.32
w/4 MN193-BK SensorsAEMC® Introduces the NEW Power Quality Analyzer PowerPad® III Model 8336
The PowerPad® III Model 8336 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three-phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV and 1000V CAT III.
The Model 8336 has 2GB of memory available for storing trend data. Additional internal memory is used to let you store alarms, transients, and snapshot data. The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input or inrush data for up to 10 minutes, and 10,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks or even months. Inrush current can also be captured and stored.
Features:
- Measurement of TRMS voltages up to 1000Vrms AC/DC for two-, three-, four- or five-wire systems
- Measurement of TRMS currents up to 10,000Arms (sensor dependent)
- Direct measurement of neutral current & voltage
- Frequency measurement (40 to 69Hz)
- Record and display trend data as fast as once per second for one month for up to 41 variables
- Transient detection on all V and I inputs (up to 210)
- Measures harmonics (referenced to the fundamental or RMS Value) for voltage, current or power up to the 50th harmonic
- Recording, time stamping and characterization of disturbance (swells, sags, and interruptions, exceedence of power and harmonic thresholds)
- 2GB SD Card for Trend Recording memory; Alarm, Snapshot, Transient and Inrush stored in internal flash memory
- 65µs/sample trend recording
- Includes FREE DataView® software for configuring data storage, real-time display, analysis and report generation
Applications: 2006 dodge caravan manual download.
- Verification of power distribution circuits
- In-plant troubleshooting of power distribution panels and individual machinery
- Monitor pad mount transformers and phase unbalances
- Determine harmonic problems originating from source or load
- Determine transformer Factor-K
- Energy metering (kVAh, VARh, kWh)
Chauvin Arnoux / Metrix Paris
The C.A 8336 is equipped with 4 voltage measurement channels and 4 current measurement channels. The C.A 8336 captures and records all the parameters, transients, alarms and waveforms simultaneously. When current sensors are connected to the C.A 8336, it recognizes them automatically.
190, rue Championnet
75876 Paris Cedex 18
Paris - FranceTel: +33 01 44 85 44 85
Fax: +33 01 46 27 73 89
E-mail:info@chauvin-arnoux.frChauvin Arnoux Ltd
United Kingdom - IrelandUnit 1 Nelson Ct, Flagship Sq Shaw Cross Business Pk
WF12 7TH
Dewsbury West Yorkshire - UKTel: +44 1924 460 494
Fax: +44 1924 455 328
E-mail : info@chauvin-arnoux.co.ukShanghai Pujiang Enerdis Instruments Co Ltd
China - Taiwan - Hong KongNo.381 Xiang De Road - 3 Floor, Building 1
200081
Shanghai - ChinaTel: +86 21 65 21 51 96
Fax: +86 21 65 21 61 07
E-mail: info@chauvin-arnoux.com.cnCA Mätsystem AB
Sweden - Denmark - Finland - NorwaySjöflygvägen 35
SE-183 62
Taby - SwedenTel: +46 8 50 52 68 00
Fax: +46 8 50 52 68 10
E-mail:info@camatsystem.comChauvin Arnoux Middle East
Bahrain - Egypt - UAE - Jordan - Kuwait - Palestine - Qatar - Sudan - Sultanate of Oman - YemenPO Box 60-154
1241 2020
Beirut - LebanonEverybody in the company loves our new user guides, and so do our customers.Manula is super easy to use. This was such a welcome change from our experience with Doc-to-Help support.Our Word-based documents were more technical than most: almost 100% tables-embedded-into-other-tables and complex layers of numbered and bulleted lists. It has been time-consuming (but fun) to convert our first thousand pages of help into Manula’s Textile-based format. How to create user guide. The few times I needed support, I got a fast, accurate reply; and the solution was always very simple.
Tel: +961 1 890 425
Fax: +961 1 890 424
E-mail:camie@chauvin-arnoux.comChauvin Arnoux GesmbH
Austria - HungarySlamastrasse 29/2/4
1230
Wien - AustriaTel: +43 1 61 61 9 61
Fax: +43 1 61 61 9 61-61
E-mail:vie-office@chauvin-arnoux.atMarshmallow manual wont download. Android Marshmallow 6.0 can run on most phones released in last 2-5 years. Unlike Windows update, new Android versions actually does not require latest hardware.
AMRA - Chauvin Arnoux
ItalyVia Sant'Ambrogio, 23
20846
Macherio (MB) - ItalyTel: +39 039 245 75 45
Fax: +39 039 481 561
E-mail:info@amra-chauvin-arnoux.itChauvin Arnoux Ibérica S.A.
Chauvin Arnoux Ca 8336 Manual
Spain - Portugal - CubaC/ Roger de Flor n°293 - 1a Planta
08025
Barcelona - SpainTel: +34 902 20 22 26
Fax: +34 934 59 14 43
E-mail:comercial@chauvin-arnoux.esChauvin Arnoux GmbH
GermanyOhmstrasse 1
77694
Kehl / Rhein - GermanyTel: +49 7851 99 26-0
Fax: +49 7851 99 26-60
E-mail:info@chauvin-arnoux.deChauvin Arnoux AG
Switzerland - LiechtensteinMoosacherstrasse 15
8804 AU
Zurich - SwitzerlandTel: +41 44 727 75 55
Fax: +41 44 727 75 56
E-mail:info@chauvin-arnoux.chChauvin Arnoux Energy
16 rue Georges Besse
Silic 44
92182
Antony - FranceChauvin Arnoux Inc
Tel: +33 1 75 60 10 30
Fax: +33 1 46 66 62 54
E-mail:info@enerdis.frPyrocontrole
Chauvin Arnoux Dover
6 bis, av. du Docteur Schweitzer
69330
Meyzieu - FranceChauvin Arnoux Ca8336
Tel: +33 4 72 14 15 40
Fax: +33 4 72 14 15 41